MOQ : 20 Piece Pieces

Automatic Changeover With Current Limiter (ACCL) Specification

  • Rated Short Circuit Making Current
  • 14kA
  • Phase
  • Single Phase
  • Mechanical Life
  • 10,000 operations
  • Rated Short Circuit Breaking Current
  • 10kA
  • Breaking Capacity
  • 10kA
  • Product Type
  • Automatic Changeover With Current Limiter (ACCL)
  • Installation Options
  • DIN Rail Mounting
  • Function
  • Automatic changeover between main supply and generator, current limiting
  • Poles Number
  • Double Pole (2P)
  • Rated Voltage
  • 240V AC
  • Rated Current
  • Up to 63A
  • Rated Frequency
  • 50Hz
  • Curves
  • Type C
  • Temperature Protection
  • Integrated thermal protection
  • Weight
  • 800g (approx.)
  • Color
  • White and Grey
  • Indication
  • LED status indicator for supply and trip status
  • Standards Compliance
  • IEC 60947-3
  • Control Method
  • Electromechanical relay based switching
  • Humidity Tolerance
  • Up to 95% RH (non-condensing)
  • Usage
  • Residential, Commercial, and Industrial applications
  • Housing Material
  • High quality flame-retardant polycarbonate
  • Mounting Dimensions
  • Standard modular size, 36mm width
  • Response Time
  • < 1 second switching time
  • Ambient Temperature Range
  • -10C to 55C
 

Automatic Changeover With Current Limiter (ACCL) Trade Information

  • Minimum Order Quantity
  • 20 Piece Pieces
  • FOB Port
  • Jaipur,Neemrana,Alwar
  • Payment Terms
  • Telegraphic Transfer (T/T), Cash in Advance (CID), Cheque
  • Delivery Time
  • 7 Week
  • Sample Policy
  • Contact us for information regarding our sample policy
  • Main Domestic Market
  • All India
  • Certifications
  • GEM,GST
 

About Automatic Changeover With Current Limiter (ACCL)

Complying to IEC 60947-6 & IEC 60947-3

Utilization Category AC 32A

Rating : Mains - 30A, DG - 0.5A-30A

Individual LED for Mains & DG

Quick transfer time

Fault Annunciation

Higher electrical life

Low blackout time

Din Rail mounting

Auto Reset Facility

Can be used for new installation as well as for retrofits



Reliable Power Switching and Protection

Engineered for precision, the ACCL provides automatic transition between utility power and generator supply without manual intervention, prioritizing safety and reliability. The current limiter function ensures electrical systems are protected from overloads, while thermal protection safeguards against high-temperature scenariosmaking it suitable for diverse environmental conditions.


User-Friendly Design and Flexible Installation

Featuring an easily visible LED status indicator for supply and trip states, the ACCL enables quick monitoring of operational status. Its compact, modular 36mm width facilitates installation in DIN rail systems, allowing for simple integration into new or existing wiring setups in homes, offices, factories, and commercial spaces.

FAQs of Automatic Changeover With Current Limiter (ACCL):


Q: How does the ACCL perform automatic changeover between main supply and generator?

A: The ACCL utilizes electromechanical relay-based switching to sense when the main supply fails and automatically transitions to the generator supply within 1 second, ensuring minimal disruption to connected equipment.

Q: What is the process for installing the ACCL in residential or commercial setups?

A: The ACCL supports DIN rail mounting with a standard 36mm modular width, making it straightforward to fit into most distribution boards. Installation should be performed by a qualified electrician to ensure safe and compliant operation.

Q: When should one use ACCL with integrated current limiting and thermal protection?

A: ACCL devices are recommended for scenarios requiring automatic source changeover and protection from excess current, especially where safeguarding sensitive appliances or maintaining uninterrupted power is critical, such as residential complexes and commercial buildings.

Q: Where can this ACCL be purchased in India?

A: The ACCL is available from distributors, manufacturers, service providers, suppliers, traders, and wholesalers throughout India, offering broad access for various project needs.

Q: What benefits does the flame-retardant polycarbonate housing provide?

A: The high-quality flame-retardant polycarbonate housing offers enhanced durability and safety, protecting the internal circuitry from fire hazards and ensuring sustained performance even in demanding environments.

Q: How does the LED status indicator assist users in monitoring the ACCL?

A: The integrated LED indicator provides clear visual signals for both supply and trip status, enabling users to quickly assess operational conditions and respond proactively to any issues.

Q: What is the humidity and temperature tolerance of the ACCL device?

A: The ACCL functions reliably in environments with up to 95% relative humidity (non-condensing) and ambient temperatures ranging from -10C to 55C, making it suitable for deployment across diverse geographic regions in India.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Circuit Breaker Category

Electrical Residual Current Circuit Breaker (RCCB)

Electrical Residual Current Circuit Breaker (RCCB)

Price 3735 INR / Piece

Minimum Order Quantity : 10 Pieces

Installation Options : DIN Rail Mounting

Rated Voltage : 240V/415V AC Volt (V)

Color : White with grey switch

Phase : other, Single Phase/Three Phase

MCB 3Pole 6-63Amp

MCB 3Pole 6-63Amp

Installation Options : DIN Rail Mounting

Rated Voltage : 230/415V AC

Color : White & Black

Phase : Three Phase

Air Circuit Breaker

Air Circuit Breaker

Minimum Order Quantity : as per requirement Piece

Installation Options : Fixed and Withdrawable

Rated Voltage : 415V AC, Up to 690V AC

Color : Black/Grey

Phase : Three Phase

MCCBs for Motor back-up Protection

MCCBs for Motor back-up Protection

Price 10168 INR / Piece

Minimum Order Quantity : 100 Pieces

Installation Options : Wall Mounted

Rated Voltage : 220 Volt(v)

Color : White

Phase : other, Single



Back to top